About Sparky Tools: Electrician Calc

Sparky Tools is a set of electrician's calculators set up for Europe: 230 V and 400 V, 50 Hz, square millimetres, metres and the IEC 60364 cable tables. Big inputs, a number pad with 64 dp keys and high-contrast screens make it usable on site, with gloves on.

Six calculators on one board
• Voltage drop: single or three phase, any copper section from 1.5 to 240 mm², with cos φ. A panel meter shows the volts left at the far end against the limit (3 % lighting, 5 % other uses), then PASS or FAIL, the next section's drop and the longest run the cable allows.
• Cable size: from the breaker, length, installation method (A1, A2, B1, B2, C, D1), PVC or XLPE, ambient or ground temperature and grouping. You get the smallest section that passes both current and voltage drop, why the size below fails, and the table lines so you can check it yourself.
• Breaker size: from a load in kW or A and the cable, the rating that meets Ib ≤ In ≤ Iz and I2 ≤ 1.45 Iz, for MCB curves B, C, D or gG fuses, drawn on one ampere scale.
• Earth loop: in TN systems, the circuit's Zs (Ze plus R1 + R2 at operating temperature) against the maximum for the breaker, plus a measured value and the longest run. In TT systems, the earth electrode resistance against the RCD's limit.
• Conduit fill: add the cables (H07V-U, H07V-R, H07V-K, XVB) and see the smallest rigid or flexible conduit within one third (or 40 %) of the bore, drawn end-on to scale.
• Ohm and power: any two of voltage, current, resistance or impedance and power give the other two, in DC, single phase or balanced three phase.

Made for Belgium, usable elsewhere
• Belgium (RGIE/AREI Book 1) is the default: Table 4.11 limits on the protective device per section, the extra non-tripping condition of 4.4.3.2, the earth electrode limit for dwellings and the RCD rules are applied or explained.
• 3N×400 V and 3×230 V networks are both supported.
• For other countries the app uses the IEC 60364 values and says so.

Jobs and work notes
• Save any result to a job with the circuit's name.
• Add values measured on site: earth loop, RCD trip time and current, insulation resistance, earth electrode, continuity.
• Write a note, add your name, sign with a finger.
• Send the work note as an A4 PDF, or as text, to any app on your phone.
• Tap a saved calculation to open it again with the same inputs.

Every value can be checked
• A Tables tab lists the current-carrying capacities, correction factors, maximum Zs values, conductor resistances and installation methods the calculators use.
• Each table was checked against two independent published sources. The formulas and sources are listed in the app.

What it is not
• Copper conductors only. Methods E, F and G, direct-buried cables, groups of buried cables, fuse earth loop checks and short-circuit withstand are not included.
• A calculation helps with a design. It does not certify an installation. Every result says to check against local rules.

Privacy
• No internet permission, no account, no ads, no analytics. Jobs stay on your phone and are left out of backups. A note leaves the phone only when you send it.