About Poll S7
View and modify your Siemens PLC data from your phone or tablet.
With a Wi-Fi or Ethernet connection to the PLC network, Poll S7 communicates via the S7Comm protocol (ISO-on-TCP, port 102), obtaining the device's IP address, rack, and slot.
Compatible with S7-1200, S7-1500, S7-300, S7-400, S7-200 SMART, and S7-200, and with S7Comm-compatible devices.
Supported Addresses:
• Data Blocks: DB1.DBX0.0, DB1.DBB2, DB1.DBW4, DB1.DBD8
• Flags: M0.1, MB2, MW10, MD20
• Inputs and Outputs: I0.0, IW64, Q0.0, QW80
• S7-200 V Memory: VW100
Data Types: BOOL, BYTE, CHAR, WORD, INT, DWORD, DINT, REAL, and LREAL.
Tapping a variable in the list writes a new value to the PLC.
Optional name for each variable: "Name = value" is displayed, followed by the address.
Integer values can be viewed and written in decimal, hexadecimal, and binary.
Communication profiles for saving the configuration of multiple PLCs.
The free version allows up to 10 variables per profile and 2 profiles, and displays advertising. Poll S7 Pro adds S7 server mode, unlimited variables and profiles, and is ad-free.
S7-1200/1500: In TIA Portal, enable "Allow access via PUT/GET communication" and disable "Optimized block access" for the databases you want to read.
SIMATIC, S7-200, S7-300, S7-400, S7-1200, S7-1500, and TIA Portal are trademarks of Siemens AG. This app is not affiliated with Siemens.
With a Wi-Fi or Ethernet connection to the PLC network, Poll S7 communicates via the S7Comm protocol (ISO-on-TCP, port 102), obtaining the device's IP address, rack, and slot.
Compatible with S7-1200, S7-1500, S7-300, S7-400, S7-200 SMART, and S7-200, and with S7Comm-compatible devices.
Supported Addresses:
• Data Blocks: DB1.DBX0.0, DB1.DBB2, DB1.DBW4, DB1.DBD8
• Flags: M0.1, MB2, MW10, MD20
• Inputs and Outputs: I0.0, IW64, Q0.0, QW80
• S7-200 V Memory: VW100
Data Types: BOOL, BYTE, CHAR, WORD, INT, DWORD, DINT, REAL, and LREAL.
Tapping a variable in the list writes a new value to the PLC.
Optional name for each variable: "Name = value" is displayed, followed by the address.
Integer values can be viewed and written in decimal, hexadecimal, and binary.
Communication profiles for saving the configuration of multiple PLCs.
The free version allows up to 10 variables per profile and 2 profiles, and displays advertising. Poll S7 Pro adds S7 server mode, unlimited variables and profiles, and is ad-free.
S7-1200/1500: In TIA Portal, enable "Allow access via PUT/GET communication" and disable "Optimized block access" for the databases you want to read.
SIMATIC, S7-200, S7-300, S7-400, S7-1200, S7-1500, and TIA Portal are trademarks of Siemens AG. This app is not affiliated with Siemens.
What’s new
Version 1.0.0 · Updated October 26, 2026
Primera versión de Poll S7: lee y escribe variables de PLC Siemens S7 por S7Comm desde Android.
Alternatives to Poll S7
Looking for apps like Poll S7? Here are 5 similar Android apps on Google Play. 4 of the 5 are free to download.
| App | Rating | Price | Installs | Last updated | Compare |
|---|---|---|---|---|---|
| Poll S7 | – | Free | 0+ | Oct 26, 2026 | |
| Poll HMI | – | Free | 0+ | Oct 26, 2026 | Compare |
| Poll OPC UA | – | Free | 0+ | Oct 26, 2026 | Compare |
| Poll Modbus Pro | – | 4.99 USD | 0+ | Oct 26, 2026 | Compare |
| Poll Modbus | – | Free | 10,000+ | Jul 18, 2025 | Compare |
| Calculator | – | Free | 100+ | Jul 1, 2023 | Compare |
Compare Poll S7 with the top alternatives: ratings, updates, ASO score and keyword gaps →